{"id":16844,"date":"2018-09-21T04:30:48","date_gmt":"2018-09-21T04:30:48","guid":{"rendered":"http:\/\/0"},"modified":"2025-01-09T13:55:15","modified_gmt":"2025-01-09T13:55:15","slug":"ultima-smart-toric","status":"publish","type":"page","link":"https:\/\/eyeol.co.uk\/twb\/hydrophilic-iols\/ultima-smart-toric\/","title":{"rendered":"Ultima Smart Toric"},"content":{"rendered":"<div class=\"vgblk-rw-wrapper limit-wrapper\"><h2>\n\tUltima Smart Toric\n\t<\/h2>\n<h4>\n\tToric IOLs\n\t<\/h4>\n<h4>\n\tCustomized Optic Size &amp; Overall Length for Each Patient\n\t<\/h4>\n<h3>\n\tBrochure\n\t<\/h3>\n\t<p>Get the detailed specifications and table.<\/p>\n\t<a href=\"https:\/\/eyeol.co.uk\/twb\/wp-content\/uploads\/2018\/10\/UST.pdf\" target=\"_self\" role=\"button\">\n\t\t\t\t\tDownload PDF\n\t<\/a>\n\t\t\t\t<img decoding=\"async\" src=\"http:\/\/eyeol.co.uk\/twb\/wp-content\/uploads\/2018\/10\/ust.jpg\" alt=\"ust\" itemprop=\"image\" title=\"ust\"  \/>\n<h2>\n\t\n\t<\/h2>\n<h2>\n\tDescription\n\t<\/h2>\n\t<p>UST is a proprietary Hydrophilic Acrylic material with yellow tint mimics to the adult natural lens. Optimized manufacturing process to ensure predictable outcome. consistent repeatability, optimum flexibility, superior surface quality, true square edge with minimal edge radius, power accuracy, asphericity. UST ensures perfect stability inside the capsular bag, lowering incidence of PCO.<\/p>\n<h2>\n\tFeatures\n\t<\/h2>\n\t<ul>\n<li>Customized optic size &amp; overall length for each patient.<\/li>\n<li>Ensures predictable refractive outcome.<\/li>\n<li>Optimized negative asphericity for each diopter.<\/li>\n<li>Plate haptic design with anti-rotational haptic pads.<\/li>\n<li>Optimized ELP design based on axial length, capsular bag size &amp; ACD.<\/li>\n<\/ul>\n<h2>\n\tSpecifications\n\t<\/h2>\n<h4>\n\t\t\t<a href=\"https:\/\/nex.vamtam.com\/products-solutions\/industrial-construction\/\" title=\"A Constant\" target=\"_self\">\n\tA Constant\n\t\t\t<\/a>\n\t<\/h4>\n\t118.0 (Suggested)<br \/>\n.\n<h4>\n\t\t\t<a href=\"https:\/\/nex.vamtam.com\/products-solutions\/industrial-construction\/\" title=\"Haptic Material\" target=\"_self\">\n\tHaptic Material\n\t\t\t<\/a>\n\t<\/h4>\n\t<p>Natural Yellow Acrylic<\/p>\n<h4>\n\t\t\t<a href=\"https:\/\/nex.vamtam.com\/products-solutions\/mechanical-engineering\/\" title=\"Optic Diameter\" target=\"_self\">\n\tOptic Diameter\n\t\t\t<\/a>\n\t<\/h4>\n\tCustomized from 5 mm to 6.5 mm<br \/>\n(0.25 Steps)\n<h4>\n\t\t\t<a href=\"https:\/\/nex.vamtam.com\/products-solutions\/industrial-construction\/\" title=\"Haptic Angulation\" target=\"_self\">\n\tHaptic Angulation\n\t\t\t<\/a>\n\t<\/h4>\n\t0\u00ba<br \/>\n(Planar)\n<h4>\n\t\t\t<a href=\"https:\/\/nex.vamtam.com\/products-solutions\/oil-gas-energy\/\" title=\"Optic Design\" target=\"_self\">\n\tOptic Design\n\t\t\t<\/a>\n\t<\/h4>\n\tModified refractive-diffractive<br \/>\n&#038; aspheric surface\n<h4>\n\t\t\t<a href=\"https:\/\/nex.vamtam.com\/products-solutions\/industrial-construction\/\" title=\"IOL Powers\" target=\"_self\">\n\tIOL Powers\n\t\t\t<\/a>\n\t<\/h4>\n\tCustomized from +1 D to +10 D<br \/>\n(0.5 D Steps)\n<h3>\n\tStats &amp; Charts\n\t<\/h3>\n\t<table>\n    <tr>\n        <th>Material<\/th>\n        <td>Natural Yellow Acrylic<\/td>\n    <\/tr>\n    <tr>\n        <th>UV &#038; HB<\/th>\n        <td>440nm<\/td>\n    <\/tr>\n    <tr>\n        <th>A Constant<\/th>\n        <td>118.0<\/td>\n    <\/tr>\n    <tr>\n        <th>Optic Diameter<\/th>\n        <td>Customized from 5mm to 6.5mm (0.25 Steps)<\/td>\n    <\/tr>\n    <tr>\n        <th>Optic Length<\/th>\n        <td>Customized from 11mm to 15mm (0.25 Steps)<\/td>\n    <\/tr>\n    <tr>\n        <th>Optic Type<\/th>\n        <td>Biconvex Toric Aspheric Optic<\/td>\n    <\/tr>\n    <tr>\n        <th>Haptic Configuration<\/th>\n        <td>Modified Plate Haptic<\/td>\n    <\/tr>\n    <tr>\n        <th>Haptic Angulation<\/th>\n        <td>0\u00ba (Planar)<\/td>\n    <\/tr>\n    <tr>\n        <th>Cylinder Power IOL Plane<\/th>\n        <td>Customized from +1D to +10D (0.5 Steps)<\/td>\n    <\/tr>\n    <tr>\n        <th>Water Content<\/th>\n        <td>26%<\/td>\n    <\/tr>\n<\/table>\n<\/div><!-- .vgblk-rw-wrapper -->","protected":false},"excerpt":{"rendered":"<p>Ultima Smart Toric Toric IOLs Customized Optic Size &amp; Overall Length for Each Patient Brochure Get the detailed specifications and table. Download PDF Description UST is a proprietary Hydrophilic Acrylic material with yellow tint mimics to the adult natural lens. Optimized manufacturing process to ensure predictable outcome. consistent repeatability, optimum flexibility, superior surface quality, true&#8230;<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":12320,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-16844","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/eyeol.co.uk\/twb\/wp-json\/wp\/v2\/pages\/16844","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/eyeol.co.uk\/twb\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/eyeol.co.uk\/twb\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/eyeol.co.uk\/twb\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/eyeol.co.uk\/twb\/wp-json\/wp\/v2\/comments?post=16844"}],"version-history":[{"count":11,"href":"https:\/\/eyeol.co.uk\/twb\/wp-json\/wp\/v2\/pages\/16844\/revisions"}],"predecessor-version":[{"id":17573,"href":"https:\/\/eyeol.co.uk\/twb\/wp-json\/wp\/v2\/pages\/16844\/revisions\/17573"}],"up":[{"embeddable":true,"href":"https:\/\/eyeol.co.uk\/twb\/wp-json\/wp\/v2\/pages\/12320"}],"wp:attachment":[{"href":"https:\/\/eyeol.co.uk\/twb\/wp-json\/wp\/v2\/media?parent=16844"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}